Electrical Energy Storage
Model of an ideal electrical battery energy storage.
Attributes, Units and Remarks
Type Model
Attribute |
Unit |
Remarks |
---|---|---|
uuid |
– |
|
id |
– |
Human readable identifier |
capex |
€ |
Capital expenditure to purchase one entity of this type |
opex |
€ / MWh |
Operational expenditure to operate one entity of
this type
|
eStorage |
kWh |
Battery capacity |
sRated |
kVA |
Rated apparent power |
cosphiRated |
– |
Rated power factor |
pMax |
kW |
Maximum permissible active power
infeed or consumption
|
activePowerGradient |
% / h |
Maximum permissible rate of change of power |
eta |
% |
Efficiency of the electrical inverter |
dod |
% |
Maximum permissible depth of discharge. 80 % dod
is equivalent to a state of charge of 20 %.
|
lifeTime |
h |
Permissible hours of full use |
lifeCycle |
– |
Permissible amount of full cycles |
Entity Model
Attribute |
Unit |
Remarks |
---|---|---|
uuid |
– |
|
id |
– |
Human readable identifier |
operator |
– |
|
operationTime |
– |
Timely restriction of operation |
node |
– |
|
qCharacteristics |
– |
Reactive power characteristic to follow |
type |
– |
|
behaviour |
– |
Foreseen operation strategy of the storage.
Eligible input: “market”, “grid”, “self”
|
Caveats
The field behaviour
will be removed in version 1.x, as this is an information, that is only important to a
smaller sub set of simulation applications.