Electrical Energy Storage
Model of an ideal electrical battery energy storage.
Attributes, Units and Remarks
Type Model
Attribute |
Unit |
Remarks |
|---|---|---|
uuid |
||
id |
Human readable identifier |
|
capex |
€ |
Capital expenditure to purchase one entity of this type |
opex |
€ / MWh |
Operational expenditure to operate one entity of this type |
eStorage |
kWh |
Battery capacity |
sRated |
kVA |
Rated apparent power |
cosPhiRated |
Rated power factor |
|
pMax |
kW |
Maximum permissible active power infeed or consumption |
activePowerGradient |
Maximum permissible rate of change of power |
|
eta |
Efficiency of the electrical inverter |
Entity Model
Attribute |
Unit |
Remarks |
|---|---|---|
uuid |
||
id |
Human readable identifier |
|
operator |
||
operationTime |
Timely restriction of operation |
|
node |
||
qCharacteristics |
Reactive power characteristic to follow |
|
type |
||
behaviour |
Foreseen operation strategy of the storage. Eligible input: “market”, “grid”, “self” |
|
em |
UUID reference to an Energy Management Unit that is controlling this system participant. Field can be empty or missing, if this participant is not controlled. |
Caveats
The field behaviour will be removed in version 1.x, as this is an information, that is only important to a
smaller sub set of simulation applications.