Node
Representation of an electrical node, with no further distinction into bus bar, auxiliary node or others.
Attributes, Units and Remarks
Attribute |
Unit |
Remarks |
uuid |
– |
|
id |
– |
Human readable identifier |
operator |
– |
|
operationTime |
– |
Timely restriction of operation |
vTarget |
p.u. |
Target voltage magnitude to be used by voltage regulation entities |
slack |
– |
Boolean indicator, if this nodes serves as a slack node in power
flow calculation
|
geoPosition |
– |
Geographical location |
voltLvl |
– |
Information of the voltage level (id and nominal voltage) |
subnet |
– |
Sub grid number |
Caveats
System participants, that need to have geographical locations, inherit the position from the node.
If the overall location does not play a big role, you are able to use the default location with
NodeInput#DEFAULT_GEO_POSITION
being located on TU Dortmund university’s campus (See on OpenStreetMaps).