Electrical Energy Storage

Model of an ideal electrical battery energy storage.

Attributes, Units and Remarks

Type Model

Attribute

Unit

Remarks

uuid

id

Human readable identifier

capex

Capital expenditure to purchase one entity of this type

opex

€ / MWh

Operational expenditure to operate one entity of
this type

eStorage

kWh

Battery capacity

sRated

kVA

Rated apparent power

cosPhiRated

Rated power factor

pMax

kW

Maximum permissible active power
infeed or consumption

activePowerGradient

% / h

Maximum permissible rate of change of power

eta

%

Efficiency of the electrical inverter

dod

%

Maximum permissible depth of discharge. 80 % dod
is equivalent to a state of charge of 20 %.

lifeTime

h

Permissible hours of full use

lifeCycle

Permissible amount of full cycles

em

UUID reference to an Energy Management Unit that is controlling
this system participant. Field can be empty or missing, if this participant
is not controlled.

Entity Model

Attribute

Unit

Remarks

uuid

id

Human readable identifier

operator

operationTime

Timely restriction of operation

node

qCharacteristics

Reactive power characteristic to follow

type

behaviour

Foreseen operation strategy of the storage.
Eligible input: “market”, “grid”, “self”

Caveats

The field behaviour will be removed in version 1.x, as this is an information, that is only important to a smaller sub set of simulation applications.